Working Pressure and Temperature
Range
Super Speedfit fittings are suitable
for the following pressures and temperatures.
| Temp |
Pressure |
5/32"
to 5/16"
(4mm to 8mm) |
3/8"
to 1/2"
(10mm to 22 mm) |
| Air |
–4ºF
(–20ºC) |
230 psi
(16 Bar) |
150 psi
(10 Bar) |
| Potable Liquids and Air |
+33ºF
(+1ºC) |
230 psi
(16 Bar) |
150 psi
(10 Bar) |
+73ºF
(+23ºC) |
230 psi
(16 Bar) |
150 psi
(10 Bar) |
+158ºF
(+70ºC) |
150 psi
(10 Bar) |
100 psi
(7 Bar) |
Also suitable for vacuum
Depending on the tube used, under certain conditions
fittings may be used at higher pressures and temperatures. Please refer
to our Customer Services Department for guidance.
Note 1 Bar = 14.5
PSIG.
Tube Types
Plastic Tube — Polyethylene,
nylon, and polyurethane conforming to the tolerances shown below. For
soft tubing or thin wall tube we recommend the use of tube inserts.
Braided Tube — Use of Tube to
Hose Stems is essential when using braided tube or hose. Use of clamps to retain braided
tube on barbs is recommended.
Metal Tube (soft) — Brass, copper,
or mild steel conforming to the tolerances below.
Metal Tube (hard) — We do not
recommend Super Speedfit fittings for hard
metal tubes or chrome plated tubes.
For stainless steel and other polished metal tubes we
recommend the use of Superseal fittings. Click
here for more details.
It is essential that outside diameters be free from
score marks and that the tube be deburred before inserting the fitting.
Tube Tolerances
Super Speedfit fittings
are offered for tubes with outside diameters to the following tolerances.
Size
(inches) |
5/32 to 3/16 |
1/4 to 1/2 |
Tolerance
(inches) |
+0.001 to
–0.003 |
+0.001 to
–0.004 |
Size
(mm) |
4 to 5 |
6 to 22 |
Tolerance
(mm) |
+0.05 to
–0.07 |
+0.05 to
–0.10 |
Collet Covers
Are available as additional security against removal of the tube or to provide a simple means of color coding.
The cover is offered in a range of six colors (black, red, yellow, gray, blue, green). Please refer to our Customer Services Department.
Food Quality
All fittings are produced in Food and Drug Administration (FDA) approved materials and are therefore
recommended for food quality applications.
| |
Installation and System Testing
- Fittings and tube should be kept clean and undamaged before use.
All tube and fittings installations must be pressure tested after installation to ensure system
integrity before handing over to the final user. See also "How to make a
connection."
Chemicals
For use with chemicals or other potentially aggressive
liquids, please refer to our Customer Services Department.
Super Speedfit fittings
are not recommended for use with explosive gases, petroleum spirits, and
other fuels or for central heating systems.
Maximum Torque Values for
Threaded Fittings
| |
Threads |
1/8"
to
1/4" |
3/8"
to
1/2" |
3/4" |
Maximum
Torque |
1.0 ft. lbs.
(1.5 Nm) |
2.2 ft. lbs.
(3.0 Nm) |
2.9 ft. lbs.
(4.0 Nm) |
a. Manufacturer recommends that OEM customers consider replacing threaded ports with the
more modern Cartridge Systems
b. It is recommended that all installations are checked prior to use to determine that a seal
has been made.
c. The maximum torque figures quoted
for use with Speedfit fittings are dependent
on the mating thread conforming to the relevant US, British or International
thread standard.
Maintenance and Replacement Intervals
Generally, little maintenance is required, but as a minimum we recommend routine visual inspection.
Frequency of visual inspection will depend on severity of application and risk of failure. If after visual inspection products appear
damaged, cracked, charred, discolored, heat distorted, or corroded, they should be replaced. Any product that is or appears to be
leaking should be replaced.
Product life is affected by the severity of the application, the hostility of the working environment,
and contact with aggressive chemicals or liquids. It is therefore important that specific replacement intervals be considered by
specifiers/users/customers based on previous service life or when failure could result in unacceptable downtime, damage, or injury risk.
Cleaning and Sanitizing
Our advice to customers is to use cleaners and sanitizing agents that are above pH 4
and low in hypochlorite level.
Acetal fittings and parts that are cleaned and/or sanitized
should be rinsed immediately with copious amounts of clean tap water to
remove all traces of the cleaners. ECOLAB Oasis 133 is recommended as a suitable external cleaner for acetal products.
Polypropylene fittings offer greater resistance to aggressive
chemicals than acetal fittings. Polypropylene does not have the same mechanical
properties as acetal.
|