FilterEase
Filters with Composite
Tanks (FDA Lined & Primed), Aquamatic Diaphragm Valves,
Time Initiated Backwash |
Part
Number |
Recommended
Flow Range
GPM (LPM) |
Flow Rate |
Bed
Surface
Area
Sq. Ft. |
Backwash
Rate
GPM (LPM) |
Tank
Size
Inches |
Diaphragm
Valve
Size |
High
Quality
GPM (LPM) |
Standard
GPM (LPM) |
Peak
GPM (LPM) |
@
5 PSI
Drop
GPM (LPM) |
| FCC15P-2472 |
21-60 (80-228) |
21 (80) |
30 (114) |
60 (228) |
30 (114) |
3.1 |
31 (117) |
24 x 72 |
1.5" Composite |
| FCC20P-2472 |
30-60 (114-228) |
21 (80) |
30 (114) |
60 (228) |
30 (114) |
3.1 |
31 (117) |
24 x 72 |
2" Composite |
| FCC15C-3072 |
35-80 (133-303) |
35 (133) |
50 (189) |
80 (303) |
40 (152) |
4.9 |
49 (185) |
30 x 72 |
1.5" Cast Iron |
| FCC15P-3072 |
35-80 (133-303) |
35 (133) |
50 (189) |
80 (303) |
50 (189) |
4.9 |
49 (185) |
30 x 72 |
1.5" Composite |
| FCC20C-3072 |
50-100 (189-379) |
35 (133) |
50 (189) |
100 (379) |
60 (227) |
4.9 |
49 (185) |
30 x 72 |
2" Cast Iron |
| FCC20P-3072 |
50-100 (189-379) |
35 (133) |
50 (189) |
100 (379) |
50 (189) |
4.9 |
49 (185) |
30 x 72 |
2" Composite |
| FCC20C-3672 |
50-105 (190-398) |
50 (190) |
70 (265) |
105 (398) |
60 (227) |
7.0 |
70 (265) |
36 x 72 |
2" Cast Iron |
| FCC25C-3672 |
70-125 (265-474) |
50 (190) |
70 (265) |
125 (474) |
70 (265) |
7.0 |
70 (265) |
36 x 72 |
2.5" Cast Iron |
| FCC20P-3672 |
50-125 (190-474) |
50 (190) |
70 (265) |
125 (474) |
70 (265) |
7.0 |
70 (265) |
36 x 72 |
2" Composite |
| FCC30C-3672 |
70-140 (265-530) |
50 (190) |
70 (265) |
140 (530) |
70 (265) |
7.0 |
70 (265) |
36 x 72 |
3" Cast Iron |
| FCC30P-3672 |
70-140 (265-530) |
50 (190) |
70 (265) |
140 (530) |
75 (284) |
7.0 |
70 (265) |
36 x 72 |
3" Composite |
| FCC20P-4272 |
65-145 (246-549) |
65 (246) |
95 (360) |
145 (549) |
90 (341) |
9.6 |
96 (363) |
42 x 72 |
2" Composite |
| FCC25C-4272 |
65-145 (246-549) |
65 (246) |
95 (360) |
125 (474) |
90 (341) |
9.6 |
96 (363) |
42 x 72 |
2.5" Cast Iron |
| FCC30C-4272 |
95-190 (360-720) |
65 (246) |
95 (360) |
190 (720) |
100 (379) |
9.6 |
96 (363) |
42 x 72 |
3" Cast Iron |
| FCC30P-4272 |
65-190 (246-720) |
65 (246) |
95 (360) |
190 (720) |
100 (379) |
9.6 |
96 (363) |
42 x 72 |
3" Composite |
| FCSC20P-4872 |
85-145 (322-549) |
85 (322) |
125 (474) |
145 (549) |
100 (379) |
12.6 |
126 (477) |
48 x 72 |
2" Composite |
| FCC25C-4872 |
85-145 (322-549) |
85 (322) |
125 (474) |
120 (455) |
125 (474) |
12.6 |
126 (477) |
48 x 72 |
2.5" Cast Iron |
| FCC30C-4872 |
120-200 (455-758) |
85 (322) |
125 (474) |
200 (758) |
140 (530) |
12.6 |
126 (477) |
48 x 72 |
3" Cast Iron |
| FCC30P-4872 |
120-230 (455-871) |
85 (322) |
125 (474) |
230 (871) |
140 (530) |
12.6 |
126 (477) |
48 x 72 |
3" Composite |
| FCC30C-6367 |
135-205 (511-777) |
135 (511) |
195 (739) |
205 (777) |
175 (663) |
19.6 |
196 (742) |
63 x 67 |
3" Cast Iron |
| FCC30P6367 |
135-300 (511-1137) |
135 (511) |
195 (739) |
300 (1137) |
195 (739) |
19.6 |
196 (742) |
63 x 67 |
3" Composite |
| FCC40C-6367 |
195-318 (739-1205) |
135 (511) |
195 (739) |
400 (1515) |
195 (739) |
19.6 |
196 (742) |
63 x 67 |
4" Cast Iron |
| FCC30C-6387 |
120-240 (455-909) |
135 (511) |
240 (909) |
240 (909) |
225 (852) |
23.8 |
238 (901) |
63 x 87 |
3" Composite |
| FCC30P-6387 |
120-200 (455-758) |
135 (511) |
200 (758) |
200 (758) |
180 (682) |
23.8 |
238 (901) |
63 x 87 |
3" Cast Iron |
| FCC40C-6387 |
240-400 (909-1515) |
135 (511) |
240 (909) |
400 (1515) |
240 (909) |
23.8 |
238 (901) |
63 x 87 |
4" Cast Iron |
| FCC60C-6387 |
280-564 (1061-2137) |
135 (511) |
240 (909) |
564 (2137) |
280 (1061) |
23.8 |
238 (901) |
63 x 87 |
6" Cast Iron |
System is
unassembled (for shipping purposes) and includes all necessary
valves, tank, grades of media, underbedding, internal distributors/strainers,
drain line flow controls, and the clock/timer/stager assembly
mounted into a control box. External piping is not included.
Customer may want to consider system additions of pressure gauges,
sample cocks, vacuum breakers, flex connectors, bypass valves,
and shut-offs etc.
Cast Iron Valve available connections:
(FPT: 1.5", 2", 2.5", 3"); (Flanged: 3", 4", 6")
Plastic Valve available connections:
(MPT: 1.5"); (Male Spigot Weld: 1.5", 2"); (Female Socket Weld:
2"); (Flanged: 2", 3")
Recommended Service Flow Rates/Ranges are
based on the sq.ft. of the tank/filter bed. Slower flow rate per
sq.ft. = Better Filtration
3.5 to 7 GPM/sq.ft. = Superior filtration (5
to 20 micron nominal) with less than 5 to 10 PSI pressure drop
7 to 15 GPM/sq.ft. = High quality filtration
(20 to 50 micron nominal) with up to 10 to 20 PSI pressure drop
15 to 20 GPM/sq.ft. = Utility filtration only
with no micron rating estimate, with up to 25 to 30 PSI pressure drop
System Flow Rates as listed are
based on pressure drop curves of <2 PSI drop through the service valves.
Backwash Rates for proper bed cleaning
are best achieved at 10 to 15 GPM per sq.ft. However, valve sizes,
pipe sizes, pump sizes, water availability, and unique applications,
allow backwash variation to as low as 8 GPM/sq.ft.
Backwash Rates allow up to 25 PSI
loss through the backwash valves.
Backwash Flow Restrictors are included
and can be provided to accommodate any desired backwash flow rates.
Valve Sizes and Tank Size Pairings for
special flow rates and backwash rates may be substituted at customer
request or are application dependent.
Operating Pressure: 125 PSI (8
bar)
Maximum Temperature: 140ºF
(60ºC)
Suggested Application Flow Rates:
RO Pretreatment: 3.5 to 7 GPM/sq.ft.
Drinking Water and Process: 8 to 12 GPM/sq.ft.
Swimming Pool: 15 to 20 GPM/sq.ft. |
|