| Filters—Time Initiated Controller with Stager |
|
Model Number |
Description |
|
A148-01 |
Filter, 3 Cycle, Single Tank |
|
A151-10 |
Filter, 3 Cycle, Two Tank Parallel with
Sequential Backwash |
|
A158-03 |
Filter, 3 Cycle, Three Tank Parallel with
Sequential Backwash |
|
A158-04 |
Filter, 3 Cycle, Four Tank Parallel with
Sequential Backwash |
Please specify voltage requirement. 115VAC/60Hz
is standard. 220VAC/50Hz or 220VAC/60Hz are available.
Please specify if a 6-Day or 7-Day clock timer is required. If not specified,
a 6-Day timer is supplied |
Filters—Demand/Metered Initiated 962 Controller with Stager
(Flow
Meter Not Included - See Below) |
|
Model Number |
Description |
|
E948-01
|
Filter, 3 Cycle, Single Tank |
|
E951-10 |
Filter, 3 Cycle, Two Tank Parallel with
Sequential Backwash |
|
E958-03 |
Filter, 3 Cycle, Three Tank Parallel with
Sequential Backwash |
|
E958-04 |
Filter, 3 Cycle, Four Tank Parallel with
Sequential Backwash |
Optional Relay Output available (on single units only).
PWA Circuit Board and Key Pad Assembly available (P/N: QA-1078458).
Battery back-up capable, 9-volt rechargeable
battery sold separately (P/N: UA-1075768).
Please specify voltage requirement: 115VAC/50-60Hz standard; 220VAC/50-60Hz
available at no extra charge. |
| Softeners—Time Initiated Controller with Stager |
|
Model Number |
Description |
|
A148-00 |
Softener, 4 Cycle, Single Tank |
|
A158-TA |
Softener, Twin Alternating |
Please specify voltage requirement: 115VAC/60Hz
standard; 220VAC/50Hz or 220VAC/60Hz available.
Please specify if a 6-Day or 7-Day clock timer is required. If not specified,
a 6-Day timer is supplied |
Softeners—Demand/Metered Initiated 962 Controller with Stager
(Flow Meter Not Included - See
Below) |
|
Model Number |
Description |
|
E948-00
|
Softener, 4 Cycle, Single Tank |
|
E951-07
|
Softener, 5 Cycle, Single Tank with Timed
Brine |
|
E951-09
|
Softener, 5 Cycle, Single Tank with Timed
Refill |
|
E951-06
|
Softener, 6 Cycle, Single Tank with Timed Brine and Refill |
|
E958-TA |
Softener, Twin Alternating with 2 Status
Lights |
|
E958-TB |
Softener, Twin Alternating with Timed Brine,
No Status Lights |
|
E958-SS |
Softener, Twin Alternating with Rinse Down
Feature and 2 Status Lights |
Optional Relay Output available (on single units only).
PWA Circuit Board and Key Pad Assembly available (P/N: QA-1078458).
Battery back-up capable, 9-volt rechargeable battery sold separately (P/N: UA-1075768).
Please specify voltage requirement: 115VAC/50-60Hz standard; 220VAC/50-60Hz available at no extra charge. |
|
Model Number |
Description |
Flow Rate - GPM
(Min/Max/Peak) |
|
UA-3023532
|
1 inch Flow Meter with Stainless Steel NPT Adapters |
0.25/35/40 |
|
UA-3023536
|
2 inch Flow Meter with Stainless Steel NPT
Adapters |
2/170/250 |
Flow
Cell Flow Meters
(X = Available) |
Pipe Size
Inches (mm) |
Female Threaded
(NPT or BSP) |
Flange Mounting
(Gaskets Included,
Flanges Sold Separately) |
Flange Mounting
(Gaskets Included,
Flanges Sold Separately) |
| Cast
Iron |
316
S.S. |
Cast
Iron |
316
S.S. |
PVC |
| 3/8 (10) |
X |
X |
|
|
X |
| 1/2 (15) |
X |
X |
|
|
X |
| 3/4 (20) |
X |
X |
|
|
X |
| 1 (25) |
X |
X |
|
|
X |
| 1.25 (32) |
X |
X |
|
|
X |
| 1.5 (40) |
X |
X |
X |
X |
X |
| 2 (50) |
X |
X |
X |
X |
X |
| 2.5 (65) |
X |
X |
X |
X |
X |
| 3 (80) |
X |
X |
X |
X |
X |
| 4 (100) |
X |
X |
X |
X |
X |
| 5 (125) |
X |
X |
X |
X |
X |
| 6 (150) |
X |
X |
X |
X |
X |
| 8 (200) |
|
|
X |
X |
X |
| 10 (25) |
|
|
X |
X |
X |
| 12 (300) |
|
|
X |
X |
X |
| 14 thru 24 inch (350 thru 600 mm) pipe size available. |
|