| With proper installation
and maintenance the RO membrane module in the SWT Metals Master™
Reverse Osmosis System will reject the following substances from tap water:
Arsenic
Barium
Bicarbonate
Boron
Bromide
Cadmium
Calcium
Chloride
Copper
Cyanide
Flouride
Hardness
Iron
Lead
Magnesium
Manganese
Mercury
Nickel
Nitrate
Phosphate
Potassium
Pyrogen
Selenium
Silica
Silicate
Silver
Sodium
Strontium
Sulfate
Zinc |
94-96%
96-98%
95-96%
60-70%
93-96%
96-98%
94-97%
87-95%
98-99%
86-95%
94-96%
95-98%
95-98%
96-98%
96-98%
98-99%
96-98%
98-99%
90-96%
96-99%
87-97%
98-99%
96-98%
85-90%
95-97%
95-97%
87-98%
96-98%
98-99%
98-99% |
|
II |
The
SWT MetalsMaster™ is much more than an RO system. It
has been designed to work on water that has chemical and bacterial
contamination also. The carbon filtration modules will remove,
or significantly reduce, over 50 chemical substances that
the EPA has deemed potential carcinogens. They include:
XX |
Adipates
(diethylhexyl)
Alachor
Aldicarb
Aldicarb sulfone
Aldicarb sulfoxide
Atrazine
Benz (a) anthracine (PAH)
Benzene
Benzo (a) pyrene (PAH)
Benzo (b) floranthene (PAH)
Benzo (k) floranthene (PAH)
Beryllium
Butyl benzyl phthalate (PAE)
Cadmium
Carbofuran
Carbon tetrachloride
Chlordane
Chlorine
Chromium (+3)
Chrysene
Dalapon
Di (2-ethylhexl) adipate
Dibenz (a,h) antracene
Dibromochloropropane |
Dichlorobenzene
(meta-)
Dichlorobenzene (ortho)
Dichlorobenzene (para-)
Dichloroethane (1,2-)
Dichloroethylene (1,1-)
Dichloroethylene (cis-1,2-)
Dichloroethylene (trans-1,2)
Dichloropropane
Diethylhexyl phthalate (PAE)
Dinoseb
Diquat
Endothall
Endrin
Ethylbenzene
Ethylene dibromide (EDB)
Glyphosate
Heptachlor
Heptachlor epoxide
Hexachlorobenzene
Hexachlorocyclopentadiene
Indo (1,2,3-c,d) pyrene (PAH)
Lidane
Mercury (organic complexes)
Methoxychlor
X |
Monochlorobenzene
Organic color
Organics
Oxymal
Pentachlorophenal
Picloram
PCB's
Simazine
Styrene
3,7,8-TCDD (dioxin)
2,4-D
2,4,5-TP (silvex)
TCB's
TCE's
Tetrachloroethylene
Thallium
THM's
Toulene
Toxaphane
Vinyl chloride
Xylenes |
|
|
GENERAL
INSTALLATION AND SERVICE PARAMETERS
XX |
The
SWT MetalsMaster™ RO System will work at peak efficiency
on either municipal or ground water supplies that do not exceed
the following:
Maximum psi
TDS
Iron
Hardness
Hydrogen Sulfide
Manganese |
125 lbs.
1800 ppm
0.4 ppm
17 gr/gal
0.05 ppm
0.1 ppm |
The SWT MetalsMaster™
has been designed to give many years of trouble free service.
To keep the system operating in peak efficiency, it is recommended
that the unit be inspected every six months for possible prefilter
sediment clogging (especially if there is a lot of sediment
in the water supply). |
XX |
The
manufacturer recom-mends that the system be serviced on an
annual basis to replace the carbon filtration module and the
RO membrane module.*
* The RO membrane module may last for a much
longer period of time on relatively good water. Check with
your Water Treatment Professional for local water characteristics
and testing. |
|
|